BCSDB - CHAIN & WIRE ROPE LUBRICANT AERSOL 3050
- MSDS: BCSDB
- Manufacturer: CRC CHEMICALS
- Product Name: CHAIN & WIRE ROPE LUBRICANT AERSOL 3050
- National Stock Number: 9150-00N009319
Product Identification
Product ID:CHAIN & WIRE ROPE LUBRICANT AERSOL 3050
MSDS Date:11/01/1985
FSC:9150
NIIN:00N009319
MSDS Number: BCSDB
Responsible Party
WARMINSTER, PA 18974
Emergency Phone: 215-674-4300
Info Phone: 215-674-4300
Preparer: A.B. REED
Cage: CRCCE
Contractor
Telephone: 215-674-4300/800-424-9300
Cage: 10136
Ingredients
METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 64%
OSHA PEL 350 PPM/450 STEL
ACGIH TLV: 350 PPM/450STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PROPANE
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: 14%
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT; 9192
ISOBUTANE,PROPELLANT
CAS: 75-28-5
RTECS: TZ4300000
Fraction By Weight: 14%
OSHA PEL N/K
ACGIH TLV: N/K
OIL
Fraction By Weight: 2%
OSHA PEL 5MG/CUM OIL MIST
ACGIH TLV: N/K
ORGANO MOLYBDENUM
Fraction By Weight: 1%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:N/K
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:REPEATED OVEREXPOSURE MAY CAUSE LIVER
AND KIDNEY EFFECTS.
Explanation of Carcinogenicity:N/K
Effects of Overexposure:INHAL:HEADACHES,DIZZINESS,ANESTHESIA,AND
UNCONSCIOUSNESS.EYES:CAUSES PAIN AND SOME IRRITATION.SKIN:MAY CAUSE
IRRITATION.
Medical Cond Aggravated by Exposure:HIGH LEVELS (8000&) OF VAPOR MAY
CAUSE CARDIAC ARRHYTHMIAS.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR- APPLY ARTF RESP IF
NECESSARY.EYES:FLUSH FOR AT LEAST 15 MIN WITH LARGE AMT OF
WATER.SKIN:WASH WITH SOAP AND WATER.INGEST:DO NOT INDUCE VOMITING-
CALL PHYSICIAN.
Fire Fighting
Flash Point Method:TCC
Flash Point:<20F,-7C
Extinguishing Media:FOAM,CARBON DIOXIDE,DRY CHEMICAL
Fire Fighting Procedures:WEAR PRESSURE DEMAND SCBA AND FULL PROT
EQUIPMENT .
Unusual Fire/Explosion Hazard:FLAMMABILITY DUE TO PROPELLENT
ONLY,AEROSOLS MAY EXPLODE >130F,55C.THERMAL DECOMP PROD INCL
HCL,CO*2,POSSIBLY PHOSGENE.(SEE SUP DATA)
Accidental Release
Spill Release Procedures:USUALLY NOT PROBLEM WITH AEROSOLS.REMOVE
SOURCES OF IGNITION,VENTILATE AREA,ABSORB LIQ WITH INERT MATL AND
STORE IN CLOSED CONTR.
Neutralizing Agent:N/K
Handling
Handling and Storage Precautions:STORE IN COOL AND DRY AREA.
Other Precautions:NO SMOKING IN AREA OF USE.DO NOT USE IN GENERAL
VICINITY OF ARC WELDING,OPEN FLAMES OR HOT SURFACES.HEAT AND/OR UV
RADIATION MAY CAUSE FORMATION OF HCL AND/OR PHOSGENE
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . SCBA IF VAPOR CONCENTRATION EXCEEDS THE TLV.
(MFR)
Ventilation:MAINTAIN VAPOR CONC BELOW TLV.USE MECHANICAL MEANS IF
NECESSARY.
Protective Gloves:SOLVENT RESISTANT
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NO NORMALLY REQUIRED FOR AEROSOL USE.
Work Hygienic Practices:N/K (FP NORNL)
Supplemental Safety and Health
FIRE/EXPLOS HAZ:VAPORS HEAVIER THAN AIR AND WILL COLLECT IN LOW SPOTS.
Chemical Properties
Boiling Pt:B.P. Text:165F,74C
Vapor Density:4.5(AIR=1)
Spec Gravity:1.26
Solubility in Water:INSOLUBLE
Appearance and Odor:LIGHT BLUE LIQUID,SOLVENT ODOR
Percent Volatiles by Volume:92
Stability
Stability Indicator/Materials to Avoid:YES
N/K
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:HYDROGEN CHLORIDE,CARBON
DIOXIDE,PHOSGENE.
Disposal
Waste Disposal Methods:MATL IS HAZARDOUS WASTE AND MUST BE DISPOSED OF
IN CONFORMANCE TO FEDERAL,STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.